Bindings for a fan connected to the PWM lines

Required properties:
- compatible	: "pwm-fan"
- pwms		: the PWM that is used to control the PWM fan
- cooling-levels      : PWM duty cycle values in a range from 0 to 255
			which correspond to thermal cooling states

Example:
	fan0: pwm-fan {
		compatible = "pwm-fan";
		cooling-min-state = <0>;
		cooling-max-state = <3>;
		#cooling-cells = <2>;
		pwms = <&pwm 0 10000 0>;
		cooling-levels = <0 102 170 230>;
	};

	thermal-zones {
		cpu_thermal: cpu-thermal {
			     thermal-sensors = <&tmu 0>;
			     polling-delay-passive = <0>;
			     polling-delay = <0>;
			     trips {
					cpu_alert1: cpu-alert1 {
						    temperature = <100000>; /* millicelsius */
						    hysteresis = <2000>; /* millicelsius */
						    type = "passive";
					};
			     };
			     cooling-maps {
					map0 {
						    trip = <&cpu_alert1>;
						    cooling-device = <&fan0 0 1>;
					};
			     };
		};